Recommended Fits, Housing

The accuracy of the fits and the geometrically-correct design of all adjacent parts have a direct effect on the accuracy requirements and the dynamic properties of the bearing and the table.

  • Stationary outer ring: It is possible to do without a fit in the housing or alternatively to have a G7 fit design. In case of higher dynamic requirements, maintain a minimum clearance of 20 µm for the fit seat of the outer ring to the housing.
  • Rotating outer ring: Design the rotating housing with a J6 clearance; here a transition fit results with a tendency for clearance fit. For maximum accuracy requirements, a clearance fit of 0 is to be targeted; in case of higher speeds and prolonged operation durations, do not exceed an interference fit of 5 µm.
AXRY-EX housing fit diagram (G7 / J6, outer ring tolerance, Da, Rmax, geometric tolerances T1/T3)
AXRY-EX housing fit diagram: stationary outer ring G7, rotating outer ring J6

Housing Tolerance Table

Legend
  • Da: Nominal housing diameter (= bearing outer diameter D, mm)
  • Bearing outer Ø tolerance: Tolerance of the bearing outer diameter itself (upper / lower deviation, mm)
  • G7: Tolerance zone of the housing for a stationary outer ring (upper / lower deviation, mm)
  • J6: Tolerance zone of the housing for a rotating outer ring (upper / lower deviation, mm)
  • T1: Roundness tolerance (µm)
  • T3: Perpendicularity tolerance (µm)
  • Rmax: Maximum corner radius (mm)
Designation Housing Da
[mm]
Bearing outer Ø tolerance
[mm]
Stationary outer ring (housing G7) Rotating outer ring (housing J6) Rmax
[mm]
upperlower G7 upperG7 lowerT1 / T3 [µm] J6 upperJ6 lowerT1 [µm]T3 [µm]
AXRY 50-EX1260−0.011+0.054+0.0148+0.018−0.007550.1
AXRY 80-EX1460−0.011+0.054+0.0148+0.018−0.007550.1
AXRY 100-EX1850−0.015+0.061+0.0158+0.022−0.007770.1
AXRY 120-EX2100−0.015+0.061+0.01510+0.022−0.007770.3
AXRY 150-EX2400−0.015+0.061+0.01510+0.022−0.007770.3
ESC