Complete Order Designation Structure

The order designation for an AXRY bearing with an angle measuring system is divided into a bearing segment and a measuring ring segment, joined by MI or MA. A complete example is shown below:

Bearing segment

AXRY 260 - NGX - SBI - PRR50 - H1* - H2* - AC - JXXXX - L120 | MI - A - 3 - 500 - K

Measuring ring segment (measuring system + parameters)

The table below explains each segment of the designation above (using AXRY 260-NGX-SBI-PRR50-AC | MI-A-3-500-K as an example):

SegmentPositionExampleDescription
Bearing segmentSeriesAXRYAxial/radial roller bearing
Bore260Bearing bore [mm]
GenerationNGXNGX generation
Lubrication connectionSBIAdditionally on the inner ring (optional)
AccuracyPRR50Axial and radial runout tolerances restricted (optional)
Connection dimensionH1/H2Restricted connection dimensions H1/H2 (optional; *only for bores 580 and 650)
AlignmentACCustomized alignment for full support-ring installation (optional)
RegulationJXXXXCustomized regulation number (optional, issued by myonic)
LubricationL120Ungreased, only preserved (optional)
Measuring ring segmentMeasuring systemMI/MAMI = incremental / MA = absolute angle measuring system
Reference mark positionAA = outside, I = inside (MI only)
Graduation accuracy3±3 / ±5 / ±10 µm
Graduation period500500 / 1000 / 3000 µm (depending on MI/MA)
Reference mark typeKDistance-coded reference mark, etc. (MI only)

All suffixes are optional (those marked * apply only to bores 580/650 mm); the applicability of each measuring ring field depends on MI/MA, as detailed in the sections below. The authoritative definition of each code is given in the detail tables below.

Basic Designation (Bearing Segment)

Code Designation Description
AXRY Construction series Axial/radial roller bearing series
260 (example) Bore in mm Bearing bore (mm); available sizes: 150, 180, 200, 260, 325, 395, 460, 580, 650
NGX / NGS / EX Bearing type Bearing generation

Measuring System

The MI and MA suffixes are placed after all optional suffixes of the bearing segment and indicate the design and mounting of the measuring system.

Code Definition Description
-MI Incremental on the inner ring Incremental measuring system mounted on the inner ring
-MA Absolute on the inner ring Absolute measuring system mounted on the inner ring

MI vs MA System Comparison

Feature MI (Incremental) MA (Absolute)
Encoding method Incremental counting + distance-coded reference Absolute position encoding
Power-up position Requires a reference run (<30°) Immediately available
Measuring ring height 10 mm 14 mm
Maximum accuracy ±2 µm arc length ±1 µm arc length

Measuring Ring Parameters (Measuring Ring Segment)

After the measuring system code (MI or MA), the following parameter codes follow in order.

Notes
  • Each field code follows directly, separated by "-", e.g.: MI - A - 3 - 500 - K
  • Fields marked "MI only" do not apply to the MA system

Position of the Reference Mark

Code Definition Description Applicability
I Reference mark inside Reference mark on the inside MI only
A Reference mark outside Reference mark on the outside MI only

Graduation Accuracy

Code Accuracy
3 ±3 µm
5 ±5 µm
10 ±10 µm

Graduation Period

Code Period Applicability
500 500 µm MI only
1000 1000 µm MI and MA
3000 3000 µm MI only

Reference Marks

Code Definition Description Applicability
(No suffix) No reference mark
K Distance-coded reference mark Distance-coded reference mark MI only
RI 1 reference mark Single reference mark MI only

Optional Suffixes of the Bearing Segment

The following suffixes are placed after the bearing generation (NGX/NGS/EX) and before the measuring system code (MI/MA).

Lubrication Connection

Code Definition Description
(No suffix) Only on outer ring Lubrication connection only on the outer ring (standard for inner ring rotation)
-SBI Additionally on inner ring Additional lubrication connection on the inner ring (for outer ring rotation)

Accuracy Requirements

Code Definition Description
(No suffix) Standard Standard accuracy
-PRR50 Axial and radial runout tolerances restricted Axial and radial runout tolerances restricted
-PRR30 Axial and radial runout tolerances high precision Axial and radial runout tolerances, high precision

PRR30 is available for bores 260–650 mm only.

Connection Dimensions (*only for bores 580/650 mm)

Code Definition Description
(No suffix) Standard Standard connection dimensions
-H1 Restricted connection dimension H1 Reduced connection dimension H1
-H2 Restricted connection dimension H2 Reduced connection dimension H2

Bearing Alignment

Code Definition Description
(No suffix) Standard Standard alignment
-AC Customized alignment Customized alignment

Regulation

Code Definition Description
(No suffix) Standard Standard specification
-JXXXX Customized regulation (number is issued by myonic) Customized regulation (number issued by myonic)

Lubrication

Code Definition Description
(No suffix) Standard grease Standard grease
-L120 Bearing ungreased, only preserved (e.g. for oil lubrication) Ungreased, only preserved; for oil lubrication systems
-GXXX Special grease (number is issued by myonic) Special grease (number issued by myonic)

Size and Availability

Measuring System Applicable Bearing Series Available Bore Range [mm]
MI (Incremental) AXRY-NGX, AXRY-EX 150 – 650
MA (Absolute) AXRY-NGX, AXRY-NGS, AXRY-EX 150 – 650

Because of the measuring ring height (MI: 10 mm, MA: 14 mm), bearings with a measuring system have a correspondingly greater overall height. See the individual product data sheets for detailed dimensions.

Order Examples

Complete Designation Description
AXRY 260-NGX-MI-A-3-500-K Bore 260 mm, NGX, incremental; reference mark outside, accuracy ±3 µm, period 500 µm, distance-coded
AXRY 325-NGX-MA Bore 325 mm, NGX, absolute measuring system
AXRY 460-NGS-MA Bore 460 mm, NGS, absolute measuring system
AXRY 260-NGX-SBI-MI-A-5-1000 Bore 260 mm, outer ring rotation (SBI), incremental; accuracy ±5 µm, period 1000 µm
AXRY 395-NGX-PRR50-MA Bore 395 mm, restricted runout tolerances (PRR50), absolute measuring system
AXRY 580-NGX-SBI-PRR50-H1-H2-AC-MI-A-3-1000-K Bore 580 mm, outer ring rotation, restricted accuracy, reduced H1/H2, customized alignment, incremental; distance-coded
AXRY 650-NGX-L120-MI-I-5-1000-RI Bore 650 mm, ungreased (oil lubrication), incremental; reference mark inside, accuracy ±5 µm, single reference mark

Scope of Delivery

myonic Supply Scope

  • Bearing with measuring ring already installed
  • Threads on the outer ring for mounting the measuring head
  • Can be mounted axially or radially (2 positions each)

Measuring Head Procurement

Measuring heads must be purchased directly from Heidenhain (AMO). myonic works closely with AMO and can assist with rapid connection.

Ordering Information

For further technical details or special designs, please contact our application engineering team (sales@eb-system.com).