Guiding System Technical Data

General Information

General Application Conditions

General application range under normal operating conditions.

Parameter Value Unit
Maximum Speed 5 m/s
Maximum Acceleration 500 m/s2

Higher values are permissible but depend on carriage type, lubrication condition, preload, and load.

Operating Environment

Parameter Value Remarks
Operating Temperature Range -30 C to +80 C IP30 (for AMSABS SL)
Transport Temperature -20 C to +70 C -
Storage Conditions 0 C to +40 C DIN 50015 climate conditions
Humidity Below 75% Prevent condensation, corrosion, and dew formation

Storage Recommendations

Storage in original condition packaging is recommended. High humidity and extreme temperature changes must be avoided. Otherwise there is a risk of condensation, which may lead to corrosion and oil separation from grease.

Materials

Component Material Treatment
Rail Ball bearing steel Hardened raceway surface
Carriage Ball bearing steel Fully hardened
Rolling Elements Ball bearing steel Fully hardened
Synthetic Components POM plastic Injection molded

Safety Instructions

Safety Guidance

If the carriage is overloaded, insufficiently lubricated, or improperly maintained, the carriage may detach from the rail. Appropriate design and technical safety measures must be taken by the user to prevent any risk of carriage separation from the rail due to loss of rolling elements.

Possible safety measures include, for example, installing safety clamps around the rail. Regulations of professional associations, relevant guidelines, and application-related standards must be observed.