AMS 4B Accessories

Accessories for Incremental Measuring Ball Guide

Accessories Overview

AMS 4B series accessories include signal processing electronics, connection cables, mechanical accessories, etc., ensuring proper operation of the measuring system. Some accessories are compatible with MONORAIL BM series and AMS 3B series.

Read Head Output Options

The AMS 4B read head is integrated within the carriage, no separate ordering required. The output interface type must be specified when ordering the carriage.

Output Type Code Signal Resolution Options
Analog Output AV 1 Vpp Sine/Cosine Depends on interpolator
Digital Output DR5 TTL/RS422 5 um
DR2 TTL/RS422 2 um
DR1 TTL/RS422 1 um
DR05 TTL/RS422 0.5 um

Connection Cables

Dedicated shielded cables ensuring signal transmission quality.

Model Length Compatible Output Description
KA-AV-xxx 1m ~ 30m 1 Vpp Analog Analog signal cable
KA-DR-xxx 1m ~ 30m TTL/RS422 Digital signal cable
KA-PW-xxx 1m ~ 10m Universal Power cable

Note: xxx represents cable length (meters), e.g., KA-AV-005 = 5m analog signal cable.

Signal Interpolators

Used for signal subdivision of analog output (1 Vpp), greatly improving resolution.

Model Interpolation Factor Final Resolution Output
IK-100 x100 2 um TTL
IK-200 x200 1 um TTL
IK-400 x400 0.5 um TTL
IK-1000 x1000 0.2 um TTL
IK-2000 x2000 0.1 um TTL

Resolution Calculation: 200 um (signal period) / interpolation factor = final resolution

Mechanical Accessories

Wipers

Model Material Compatible Sizes Description
ZCV V-type Rubber 15 ~ 45 Standard V-type wiper
ZCP Polyurethane 15 ~ 45 Wear-resistant wiper
ASM Metal 15 ~ 45 For high temperature environments

End Plugs

Model Material Compatible Size
BMK 15 Plastic Size 15
BMK 20 Plastic Size 20
BMK 25 Plastic Size 25
BMK 30 Plastic Size 30
BMK 35 Plastic Size 35
BMK 45 Plastic Size 45

Cover Strips

Model Material Description
MAC Aluminum Alloy Standard aluminum cover strip
MSC Stainless Steel Stainless steel cover strip

Lubrication Options

Code Type Description Suitable Applications
LN Oil Protection Light oil protection Systems with continuous oil supply after installation
LG Grease Protection Thin layer grease protection Systems with continuous grease supply after installation
LV Standard Grease Full grease fill General applications with manual lubrication
LO Oil Lubrication For centralized lubrication systems Automatic lubrication systems

Electrical Specifications

Parameter 1 Vpp Analog TTL/RS422 Digital
Supply Voltage 5V DC +/-5% 5V DC +/-5%
Current Consumption Approx. 120 mA Approx. 150 mA
Output Load >= 10 kOhm -
Maximum Cable Length 30 m 30 m (RS422)

Selection Notes

  • Analog output (1 Vpp) requires external interpolator for use, can achieve highest resolution
  • Digital output can be directly connected to controller, but resolution is fixed
  • Cable length affects signal quality, recommend using shortest necessary length
  • High-speed applications recommend RS422 differential output
  • Cleanroom applications require dust-free lubricating grease
  • Accessories must be selected according to specific size specifications
連結已複製!