Technical Symbols and Units

The technical symbols, descriptions, and units used in this catalogue are shown in the table below. These symbols are used in calculations, specifications, and technical drawings.

Symbol Description Unit
a Event probability Factor
C0 Static load capacity N
C Dynamic load capacity for 100,000 m travel distance
For SCHNEEBERGER products, C corresponds to C100
N
C100 Dynamic load capacity for 100,000 m travel distance N
C50 Dynamic load capacity for 50,000 m travel distance N
Ceff Effective load capacity per rolling element N
Dw Diameter of rolling element mm
F Operating load, load on linear guideway N
F1... F2... Individual loads N
fh Hardness factor Factor
ft Temperature factor Factor
H Stroke mm
K Cage length mm
Kt Load-bearing (cage) length mm
L Length mm
L Rated service life m
L1 ... L2 ... Partial travel distances mm
M Moment load (longitudinal and transverse) Nm
Mds Tightening torque Ncm
ML Permissible moment load (longitudinal and transverse) Nm
MQ Permissible moment load (transverse) Nm
P Dynamic equivalent load N
PL Dynamic equivalent load (longitudinal) N
PQ Dynamic equivalent load (transverse) N
Pvs Infeed force N
Q Mean linear guideway spacing mm
RA Number of rolling elements pcs
RT Number of load-bearing rolling elements pcs
RTmin Correction factor Factor
t Cage pitch mm
t2 Intermediate segment length mm
w Distance from cage start to centre of first rolling element mm
δS Deformation of connecting structure µm
δA Deformation of rolling elements including guideway µm

Common Unit Abbreviations

Unit Descriptions

  • N - Newton (unit of force)
  • Nm - Newton metre (unit of torque)
  • Ncm - Newton centimetre (unit of torque)
  • mm - Millimetre (unit of length)
  • m - Metre (unit of length)
  • µm - Micrometre (unit of length, 1 µm = 0.001 mm)

Important Notes

Note: When performing calculations, ensure that a consistent unit system is used. All values in this catalogue are based on the International System of Units (SI).

Dual meaning of symbol L: The symbol L has different meanings in different contexts. Please determine from context whether it refers to "length" (unit: mm) or "rated service life" (unit: m).

Factor Descriptions

"Factor" in the table indicates that the parameter is a dimensionless value used for correction or adjustment in calculations. Common factors include:

  • Hardness factor (fh) - Considers the effect of material hardness on performance
  • Temperature factor (ft) - Considers the effect of operating temperature on performance
  • Correction factor (RTmin) - Used for load calculation corrections
  • Event probability (a) - Probability factor in statistical analysis
連結已複製!