AMS Measuring System Technical Data
General Technical Data
System Features
| Parameter | Value | Unit |
|---|---|---|
| Signal Period | 200 | um |
| Maximum Speed | AMSA 3B: 3 m/s AMSA 4B: 5 m/s AMSABS: 3 m/s | - |
Operating Environment
| Parameter | Value | Remarks |
|---|---|---|
| Protection Rating | IP 68 | IP 67 for AMSABS 3L |
| Operating Temperature | 0 C to +70 C | - |
| Transport Temperature | -20 C to +70 C | - |
| Storage Temperature | 0 C to +40 C | - |
| Humidity | < 75% | No chemical gases, vapors, or liquids |
| Shelf Life | 3 years | Under appropriate storage conditions |
AMSA / AMSD Incremental Measuring System Accuracy Data
AMSA 3B / AMSA 4B Analog Interface
| Parameter | AMSA 3B | AMSA 4B |
|---|---|---|
| Accuracy Class | +/- 5 um / 1000 mm +/- 2 um / 40 mm | +/- 5 um / 1000 mm +/- 2 um / 40 mm |
| Periodic Deviation | +/- 0.7 um | +/- 0.7 um |
| Resolution | Max 0.0625 um | |
| Hysteresis | < 0.5 um | |
| Interface | Analog; 1 Vpp | |
| Supply Voltage | 5 V +/- 0.25 V | |
| Current Consumption | 40 mA | 110 mA |
| Maximum Speed | 3 m/s | 5 m/s |
AMSD 3B / AMSD 4B Digital Interface
| Parameter | AMSD 3B | AMSD 4B |
|---|---|---|
| Accuracy Class | +/- 5 um / 1000 mm +/- 2 um / 40 mm | +/- 5 um / 1000 mm +/- 2 um / 40 mm |
| Periodic Deviation | +/- 0.7 um | +/- 0.7 um |
| Resolution | 0.2 / 1.0 / 5.0 um | |
| Hysteresis | < 0.5 um or digitally adjustable | |
| Interface | Digital; quadrature signal RS 422 | |
| Supply Voltage | 5 V +/- 0.25 V | |
| Current Consumption | 40 mA | 110 mA |
| Maximum Speed | 3 m/s | 5 m/s (max 1 m/s at 0.2 um resolution) |
AMSABS Absolute Measuring System Accuracy Data
AMSABS 3B / AMSABS 4B
| Parameter | TSS / TF1 / TM1 | TS1 (SSI+SinCos) | TS2 (DRIVE-CLiQ) |
|---|---|---|---|
| Accuracy Class | +/- 5 um / 1000 mm, +/- 2 um / 40 mm | ||
| Periodic Deviation | +/- 0.7 um | ||
| Resolution | Max 0.09765625 um (TM1: 0.05 um) | Max 0.09765625 um | 0.050 um |
| Hysteresis | < 0.5 um | ||
| Interface | Digital; TSS synchronous cyclic serial interface (SSI) TF1 FANUC serial interface TM1 Mitsubishi serial interface | Hybrid; synchronous cyclic serial + analog 1 Vpp | Siemens DRIVE-CLiQ protocol |
| Supply Voltage | 5 V +/- 10% or 24 V +/- 10% | 5 V +/- 10% or 24 V +/- 10% | 24 V (19VDC..31VDC) (PELV EN50178) |
| Current Consumption | < 200 mA (output unloaded) | < 50 mA (24V typical) | |
| Maximum Speed | 3 m/s | ||
AMSABS 3L (Long Type Absolute)
| Parameter | TS3 / TF1 |
|---|---|
| Accuracy Class | +/- 5 um / 1000 mm, +/- 2 um / 40 mm |
| Butt Joint Accuracy | DeltaxPP = +/- 7 um, DeltaxS1S2 = +/- 5 um |
| Periodic Deviation | +/- 0.7 um |
| Resolution | Max 0.09765625 um |
| Hysteresis | < 0.5 um |
| Interface | Hybrid; synchronous cyclic serial + analog 1 Vpp TF1 FANUC serial interface |
| Supply Voltage | 5 V +/- 10% or 24 V +/- 10% |
| Current Consumption | < 200 mA (output unloaded) |
| Maximum Speed | 3 m/s |
| Protection Rating | IP 67 |
Read Head Dimensions
AMS 3B / AMS 4B Dimension Drawing
AMSABS 3B / AMSABS 4B Dimension Drawing
AMSABS 3L Dimension Drawing
AMSABS-DC Dimension Drawing