6.2.4 System Comparison - Technical Data

SCHNEEBERGER offers distance measuring systems for various applications. The following table lists the applications and technical specifications of different systems.

Distance Measuring System Technical Data

Technical Diagram
AMSA 3B/4B AMSD 3B/4B AMSABS 3B/4B AMSA 3L
Distance Measurement
Incremental
Absolute
System Characteristics
Measuring Scale Hard magnetic periodic
N-S pole graduation
Hard magnetic periodic
N-S pole graduation
Hard magnetic periodic
N-S pole graduation
Hard magnetic periodic
N-S pole graduation
Signal Period 200 µm 200 µm 200 µm 200 µm
Equidistant Reference Marks 50 mm 50 mm - L4*
Distance Coded (Base Period) 40/100 mm 40/100 mm Absolute -
Diagnostic LED -
Maximum Scale Length
≤ 6000 mm -
> 6000 mm - - -
Integration
MONORAIL MR
MONORAIL BM/BZ -
Accuracy
Accuracy Grade / 1000 mm ± 5 µm ± 5 µm ± 5 µm ± 5 µm
Accuracy Grade / 40 mm ± 2 µm ± 2 µm ± 2 µm ± 2 µm
Periodic Deviation ± 0.7 µm ± 1 µm ± 0.7 µm ± 0.7 µm
Overall Accuracy at Joint - - - ± 7 µm
Maximum Resolution •• 0.2/1.0/5.0 µm 0.0977 µm ••
Hysteresis < 0.5 - 1 µm < 0.5 µm** < 0.5 - 1 µm < 0.5 - 1 µm
Motion
Maximum Speed 3 m/s 3 m/s 3 m/s 1 m/s
Vibration / Shock 30 g 30 g 30 g 10 g
Electrical Interface
Analog 1 VSS - - 1 VSS
Digital - Quadrature Signal
RS422 (TTL)
- -
Digital Absolute - - SSI,
SSI + 1 VSS
-
Supply Voltage 5 ± 0.25 V 5 ± 0.25 V 5 V ± 10 %
24 V ± 10 %
5 ± 0.25 V
Current Consumption (No Load) 40 mA 110 mA < 200 mA 50 mA
Mechanical Interface
S-Type Connector -
R-Type Connector -
M-Type Connector
Environment
Protection Class IP 68
(up to 0.3 bar)
IP 68
(up to 0.3 bar)
IP 68
(up to 0.3 bar)
IP 67
Operating Temperature 0°C - +70°C 0°C - +70°C 0°C - +70°C 0°C - +70°C
Storage Temperature -20°C - +70°C -20°C - +70°C -20°C - +70°C -20°C - +70°C

Note: • = Applicable, •• Limited by controller, with SMEA can reach 0.0625µm, * Except MR45, where it is 105 mm (52.5 mm at guide rail joint), ** Or digitally adjustable

連結已複製!