Series Overview

The L7 Width 100 sub-series consists of three primary part lengths — 350-100, 500-100, and 650-100 — with a 100 mm secondary part width. Peak force range 4,052 ~ 8,104 N, water-cooled continuous force 1,813 ~ 3,638 N. This is the entry-level high-efficiency, water-cooled iron-core linear motor in the L7 series.

Dimensions

L7 motor side view dimensions: L_P, L_S, B_PMAX, B_P, H_P, H_SC

Side / end view dimensions (shared across the entire series)

L7 motor top view dimensions: B, B_S, L_P

Top view dimensions (shared across the entire series)

Performance Data — Width 100

Category / Parameter Symbol Unit 350-100 500-100 650-100
Winding
WindingZ1.9HZ2.8HZ2.7H
Forces
Ultimate force (1 s)FuN4,4326,6488,864
Peak forceFpN4,0526,0788,104
Continuous force (cooled)FcwN1,8132,7003,638
Continuous force (not cooled)FcN6619511,258
Stall force (cooled)FswN1,2881,9182,584
Cogging force at I = 0FcogN8.1012.1616.21
Velocities
Limiting velocity at Ip, UDCL = 600 Vvlp600m/s1.951.901.40
Limiting velocity at Icw, UDCL = 600 Vvlw600m/s4.534.483.34
Limiting velocity at Ip, UDCL = 300 Vvlp300m/s0.820.800.54
Limiting velocity at Icw, UDCL = 300 Vvlw300m/s2.082.061.51
Currents
Effective ultimate current (1 s)Iu effA65.698.499.7
Effective peak currentIp effA52.578.779.7
Effective continuous current (cooled)Icw effA17.325.726.3
Effective continuous current (not cooled)Ic effA6.178.878.91
Effective stall current (cooled)Isw effA12.218.218.6
Power losses
Power loss at FpPlpW7,26710,90014,128
Power loss at FcwPlwW1,0521,5562,059
Power loss at FcPlcW134185236
Electrical characteristic values
DC link voltageUDCLV800800800
Electrical resistance, phase to phaseR20Ω1.761.171.48
Inductance, phase to phaseLmH29.6920.3926.51
Back EMF constantkûV/(m/s)87.787.7115.5
General characteristic values
Pole pair widthpmm464646
Motor constant (20 °C)kmN/√W66.181.094.9
Force constantkfN/A107.2107.2141.2
Motor temperature switch-offJPTC°C110.0110.0110.0
Attraction forceFaN6,2059,30712,410
Cooling conditions (medium: water, supply temperature 20 °C)
Recommended volume flow ratedV/dtl/min4.04.55.0
Cooling water temperature differenceΔJK3.85.05.9
Pressure dropΔpbar0.30.40.6

Geometric Data — Width 100

Category / Dimension Symbol Unit 350-100 500-100 650-100
Primary part
LengthLPmm384545706
WidthBPmm140140140
HeightHPmm58.558.558.5
Maximum widthBPMAXmm144.4144.4144.4
Cooling water connectionTSPC2 × G1/8″2 × G1/8″2 × G1/8″
MassmPkgca. 14ca. 20ca. 26
Secondary part
LengthLSmm184
WidthBSmm134
Height (without encapsulation)HSmm16
Height (encapsulated)HSPmm16.3
Motor installation dimensions
Width with secondary part cooling systemBmm155
Height without secondary part cooling systemHmm76
Height with secondary part cooling systemHSCmm79

Specifications subject to change without notice.

Source: Schaeffler Industrial Drives — L7 Series High Efficiency Linear Motors (PHL en-GB / DE / 2025-01).

For parameter definitions see the Type Designation & Glossary page.

ESC